   <Instrument>
      <ResourceID>spase://SMWG/Instrument/PADRE/MeDDEA</ResourceID>
      <ResourceHeader>
         <ResourceName>Measuring Directivity to Determine Electron Anisotropy (MeDDEA)</ResourceName>
         <AlternateName>PADRE/MeDDEA</AlternateName>
         <AlternateName>MeDDEA</AlternateName>
         <ReleaseDate>2026-05-30T00:08:46</ReleaseDate>
         <RevisionHistory>
            <RevisionEvent>
               <ReleaseDate>2026-06-01T00:08:46</ReleaseDate>
               <Note>Updated the description. SY</Note>
            </RevisionEvent>
         </RevisionHistory>
         <Description>MeDDEA, Measuring Directivity to Determine Electron Anisotropy, is one of the scientific instruments on the PADRE mission. It is a photon-counting hard X-ray directivity instrument that uses flight-spare detectors from the Spectrometer/Telescope for Imaging X-rays, STIX, provided by CEA-Saclay. MeDDEA measures individual photons and time-tags them with a time resolution better than 1 ms. The instrument has an energy range of approximately 3 keV to 110 keV and an energy resolution of approximately 1.1 keV at 59.5 keV. Its field of view is about 6 degrees, but it does not provide spatial resolution. MeDDEA is designed to investigate the directivity of solar flare X-ray emissions and to advance understanding of solar flare electron anisotropy.</Description>
         <Contact>
            <PersonID>spase://SMWG/Person/Steven.Christe</PersonID>
            <Role>PrincipalInvestigator</Role>
         </Contact>
         <InformationURL>
            <Name>PADRE Instrument Web Page</Name>
            <URL>https://padre.ssl.berkeley.edu/timeline/</URL>
            <Description>PADRE instrument overview page describing SHARP and MeDDEA.</Description>
         </InformationURL>
      </ResourceHeader>
      <InstrumentType>Spectrometer</InstrumentType>
      <InstrumentType>SolidStateDetector</InstrumentType>
      <InvestigationName>Measuring Directivity to Determine Electron Anisotropy (MeDDEA) on PADRE</InvestigationName>
      <OperatingSpan>
         <StartDate>2025-06-23T00:00:00</StartDate>
         <Note>StartDate is the PADRE launch date.</Note>
      </OperatingSpan>